MHLW MO 169 – Chapter 3 – Control of Nonconforming Products

By Dr. Christopher Joseph Devine

When it comes to identifying and controlling nonconforming product, place significant emphasis on the need for a robust system, premised on well-written procedures. It is always a bad thing for nonconforming product to find its way into the supply chain.

When it comes to identifying and controlling nonconforming product, place significant emphasis on the need for a robust system, premised on well-written procedures. It is always a bad thing for nonconforming product to find its way into the supply chain.

Continue reading →

Devine Guidance

MHLW MO 169 – Chapter 3 – Documents Concerned with Manufacturing and Quality Control

By Dr. Christopher Joseph Devine

Compilation of the Seihin Hyojun Sho or the Device Master File is a necessary evil for device manufacturers wanting to introduce product into the Japanese market.

Compilation of the Seihin Hyojun Sho or the Device Master File is a necessary evil for device manufacturers wanting to introduce product into the Japanese market.

Continue reading →

Dr. Christopher Joseph Devine, President, Devine Guidance International
Devine Guidance

MHLW MO 169 – Chapter 3 – Responsible Engineering Manager

By Dr. Christopher Joseph Devine
Dr. Christopher Joseph Devine, President, Devine Guidance International

The responsible engineering manager’s role is unique. A scripted procedure is recommended that clearly delineates the responsibilities as they pertain to MO 169 and Articles 65, 68, 70, and 71. It is also considered a best practice to identify the role of the responsible engineering manager on an organization chart and document the role through the use of a letter of delegation.

Continue reading →

Devine Guidance

MHLW MO 169 – Chapter 2/Section 6 – Preventive Action

By Dr. Christopher Joseph Devine

Be proactive and create just one procedure for corrective action and preventive action (CAPA). Medical device manufacturers must actually pursue PA and have documented evidence of their efforts. After all, if PA is not documented in writing, it never happened.

Be proactive and create just one procedure for corrective action and preventive action (CAPA). Medical device manufacturers must actually pursue PA and have documented evidence of their efforts. After all, if PA is not documented in writing, it never happened.

Continue reading →

Ask the Engineer

Spring Design in Product Development

By George E. Fournier

If required in the product, the spring is probably the least expensive component of the assembly. However, if it does not function as intended or fails, it can become a warranty issue which can be quite expensive as far as repair, loss of sales and product reputation.

If required in the product, the spring is probably the least expensive component of the assembly. However, if it does not function as intended or fails, it can become a warranty issue which can be quite expensive as far as repair, loss of sales and product reputation.

Continue reading →

Water – The Solvent Future

Why should we go back to using water as a solvent? Water-based chemistry has simple operations, high synthetic efficiency, safety benefits, low-cost reactions, and a high potential to generate new synthetic methodologies that can that can be patented to protect your product.

Why should we go back to using water as a solvent? Water-based chemistry has simple operations, high synthetic efficiency, safety benefits, low-cost reactions, and a high potential to generate new synthetic methodologies that can that can be patented to protect your product.

Continue reading →