Medical Device Use Error: Stop Blaming Users
One of the fundamental principles of human factors and product development is to ensure that the medical device is designed in a manner in which the user can effectively use the product. It should not be the other way around; users should not be required to adapt to the device. Unfortunately, designers do not always adhere to this philosophy. And when a use error occurs, some are quick to blame the user during the path of uncovering the root cause.
“There’s a gut instinct to think that it was the user’s fault—the user was forgetful, was careless, [and] was not paying attention… because indeed it takes a human being to make a mistake,” said Michael Wiklund, general manager of human factors engineering at Wiklund R&D, during a recent webinar, “Analyzing the Root Causes of Medical Device Use Errors”. Wiklund estimates that when use errors occur, the user is solely responsible in just one out of 100 instances. As such, he encourages the examination of the user interface itself and discourages folks from taking the easy path of blaming users for errors. “Our job as human factors specialists is to consider the possibilities of what happened.”
According to Andrea Dwyer, managing human factors specialist at Wiklund R&D, the root cause analysis process is a form of sleuthing. “It’s both a systematic, technical approach, but it requires some creativity to get to get to the true insights,” she said. It’s critical to take a structured approach to root cause analysis. Dwyer advises following seven steps during the process:
- Define and document the use error
- Identify provisional root causes
- Analyze anecdotal evidence. Talk to the person who might have committed the error to get a sense for why he or she thinks it occurred.
- Inspect the device for user interface design flaws (i.e., flaws related to hardware, software, or instructional materials associated with the device)
- Consider other contributing factors beyond the design-specific root cause that might have been considered in Step 4
- Develop a final hypothesis
- Report the results
For more details about these steps for success in getting to the root cause of use error, view the archived webinar.
Related Articles
-
The purpose of the Best Practices in Supply Chain Resiliency and Quality Working Group is to improve medical device quality and supply chain resiliency by expanding MedAccred adoption through the tiers in the supply chain, identifying best practices to supplement…
-
On May 16-17, device developers, regulatory affairs and regulatory intelligence professionals will come together in Washington, DC, for two days of education, discussion and networking to share strategies and best practices on navigating current and on the horizon regulatory requirements.
-
Jordi labs and its team of Ph.D. analytical chemists developed a proprietary, multi-detector approach to ensure that all extractables are accurately characterized to comply with global materials testing regulatory requirements.
-
Companies have several avenues available to share their input on and help shape MedTech regulation. At the 2023 MedTech Regulatory Intelligence Summit, former FDA CDRH member Steven Silverman, and Patterson Shafer, strategic advisor to FDA, offered guidance on how to…
About The Author
Maria Fontanazza
Editor-in-Chief
Maria Fontanazza has more than 15 years of experience in journalism, marketing and communications. She was previously marketing communications manager and market research manager at Secant Medical, Inc., a manufacturer of biomedical textiles and advanced biomaterials. Fontanazza also served as an editor at MD+DI and has authored articles that have appeared in domestic and international industry publications. Fontanazza has a B.A. in Journalism and Mass Communications with a concentration in New Media and Visual Design, and a Minor in Fine Arts, from St. Michael’s College in Colchester, VT. Follow her industry insights on Twitter at @MariaFontanazza. Contact Maria